Twinflex fire alarm panel user manual

Fikes comprehensive fire detection solutions range from the latest in fire. This device is compatible with the lex fire alarm control panelrange of twinf s and comprises a 2wire zonepowered manual call point mcp. We are delighted to be sponsoring the leasehold 2020 conference brought. Fike twinflexpro2 2 zone boxed kit approved 6040002. Twinflex v3 control panel user guide 5 system configuration the detectors and callpoints are arranged in zones to enable the location of a fire alarm to be identified. The feature, who looks after your fire alarm system, explains how to. I hate the twinflex pro panel as you have to program it slowly or it gets confused if you push the buttons too fast. Fike cheetah fire panel manual fire alarm control panel fike cheetah xi ground fault testing and diagnostic facp. Twinflex pro repeater panel engineering and commissioning manual end user training a fire alarm system is of little use if the end user andor the responsible persons who will be present in the building do not know how to operate and respond to the system. Due to the complexity and inherent importance of a system covering a life protection risk, training on. It is nice a simple but firstly you need the correct test key and user. Earth fault yellow will flash if a fault occurs with the earthing.

Testing fike twinflex multipoint heat detector with solo 460. The manual contains installation and operating instructions for the full range of twinflex 2, 4 and 8 zone control panels, including twinflex plus, and all of the available field devices. Twinflex and multipoint fire alarms, intruder alarms and. Fire trade supplies ltd unit 2a station yard station road melbourne derbyshire de73 8hj tel. Fike twinflexpro manuals manuals and user guides for fike twinflexpro. In this video i show a demo on testing a fike twinflex pro manual call point on a fike twinflex pro fire alarm panel. Repeater panels do not connect to or control any devices. The unit will text up to five mobile phones in the event of an alarm.

This time, we have the pleasure to collaborate with one of our main manufacturers. Due to the complexity and inherent importance of a system covering a. The panel also monitors each zone for detector head removal, device fault, end of line fault and open or short circuit fault. A maximum of 8 repeater panels can be connected to a single control panel. Twinflex pro control panel engineering and commissioning manual 5 introduction this manual is intended as a guide to the engineering and commissioning principles of the twinflex pro 2wire fire detection and alarm system and covers the system hardware information only. Leading uk based fire alarm control panel manufacturers. A conventional 2wire fire alarm system is often the natural choice for smaller applications or where budget constraints exist.

For more information on these products call us now on 01200 428 410 or use the livechat facility below. Start the selection process by pressing and holding the next option button for 3 seconds. The controls enabled led should then be illuminated. User operating instructions are provided in the first part of the manual with the following sections dealing with installation, commissioning procedures, and full technical details.

The twinflexpro2 is able to recognise and separately identify between smoke detector, heat detector and a manual call point alarm. Break glass identification on panel to differentiate. The end user is given optimum fire protection, even if the installer is unsure of the use of the particular area where the. Repeater operation the following functions are available at the repeater.

Man1082 sigma cp user conventional fire alarm control panels. Twinflexpro 2wire fire detection and alarm system and covers. Discuss fike twinflex fire alarm install in the security alarms, door entry. The twinflex twowire multipoint asd detector can be set to any one of 3 smoke modes, 3 heat modes as well as a combined mode smoke 2 and heat 2 where a smoke or heat source can trigger a fire decision see below.

However, for your convenience, the main instructions for each of ctecs product ranges typically our control panel manuals can be downloaded. Repeater panel engineering and commissioning manual. This manual is intended as a guide to the engineering and commissioning principles of the twinflex 2wire fire detection and alarm system, and covers the system hardware information only. Twinflexsrp fire suppression system remote status indicator. Mere seconds can be the difference between a minor incident and a major disaster. The twinflex pro repeater panel is connected directly to the twinflex pro fire alarm panel 4 or 8 zone only and reports events which occur on the fire alarm panel. Fike rafiki twinflex two wire fire alarm systems the safety centre are pleased to introduce the range of fike formerly rafiki two wire fire alarm system equipment. The twinflexpro control panel range offers a complete solution for your fire alarm systemall on just 2 wires twinflex control panels are available in 2, 4 or 8 zones. How to test your channel safety system sabre fire alarm. Twinflex fike uk fire, explosion and process solutions.

Welcome to the sd fire alarms fike twinflex pro panel description part 2 video. Twinflex pro control panel user guide fire alarm system notice to enable the control panel keys you may gain access to the fire alarm controls by inserting the key turning. Twinflex v3 control panel engineering and commissioning instructions 5 introduction this manual is intended as a guide to the engineering and commissioning principles of the twinflex 2wire fire detection and alarm system, and covers the system hardware information only. The number of zones depends on the size and the layout of the premises, and the capacity of the control panel. This device is only compatible with the twinflex control panels and their associated detection and alarm equipment and may also incorporate a sounder ignore all references to sounders if your device has no sounder. Indication of zonal fire, zonal fault and zonal isolate conditions operation of buzzer silence, manual evacuate, alarms silence and system reset functions indication of control panel status. Twinflex and multipoint user guide 4 introduction purpose of the guide this guide is provided to enable the person responsible for the fire alarm system see definitions to operate the system, undertake their responsibilities with regard to testing and maintenance of the system, and to record events and servicemaintenance visits.

Twinflex is the name of the range of control panels and associated devices which together form the fire alarm system installed in the premises, and is derived from. The devices communicate with the control panel using the twinflex data protocol. Twinflex v3 user guide gardiner fire and security alarms ltd. Do have a look at the manual before programming though, and the write protect switch at the top needs to be switched off when. With the twinflexpro 2wire fire alarm design, installation. The instructions apply equally to all control panels except where noted in the text. The number of zones depends on the size and the layout of the premises, and is limited to 8 zones per control panel. Evacuator synergy wireless text master evasyngsm fire. Welcome to the sd fire alarms fike twinflex pro panel description part 4 video. Addressable panels duonetquadnet brochure sita usb interface lead sita v4. A step by step guide of how to test your channel safety systems sabre fire alarm system. Code of practice for the design and installation of fire detection and alarm systems in.

Put the fire alarm panel into access level two see authorised user controls page 6. Fike cannot guarantee the operation of any equipment unless all documented instructions are complied with, without variation. Fikes policy is one of continual improvement and the right to change a specification at any time without notice is. Twinflexsrp single flood zone fire suppression system control panel. Once operated the device latches into the alarm position and requires manually resetting via a special key. Instructions and manuals are best downloaded from our individual product pages via the menu bar above.

This manual is intended as a guide to the engineering and commissioning principles of the. Multipoint asd detector fike uk fire, explosion and. Repeater panel user manual to be retained by the end user. Repeater panel engineering and commissioning manual to be retained by the commissioning engineer. For more videos in this fire alarm panel manual call point demo play list. Twinflex pro is our best selling fire alarm control panel, installed using only one pair of wires per zone and two types of devices multipoint asd detectors with optional sounder and strobe and manual callpoints.

The twinflex pro control panel also provides two monitored outputs that may be configured as conventional. The detector must be installed in compliance with the control panel installation manual. The twinflex manual call point mcp allows for user activation of the fire alarm system. Alarm silenced yellow illuminated if the sounders on the alarm circuits during a fire evacuation condition have been switched off or silenced.